http://WWW.CONTAINEROFFICEBANGALORE.COM
AMOFFICESOLUTIONS 5a1fd159b6926d0b1463b31b False 81 43
OK
background image not found
Found results for
'fire resistance hylam sheets'
Office Cabin INR   0 INR  0
-NaN%

Office Cabin

TECHNICAL SPECIFICATION SI NO COMPONENT DESCRIPTION 01 Bottom Frame 100mmx50mm G, C Channel & pipe ISI Marked. 02 Top Frame 50mmx50mm Ms Square Pipe ISI Marked. 03 Stiffener Bottom 75mmx40mm C channel Angles & pipes ISI Marked. 04 Stiffener Top 40mmx20mm MS square pipe ISI Marked. 05 Side Post 50mmx50mm Ms square pipe ISI Marked. 06 Side Wall Stiffeners Specially formed CR sheets of make TATA / Jindal. 07 Paneling Outside Specially formed CR sheets TATA / Jindal. 08 Internal Wall Paneling 8mm OSL MDF of make Leo Classic. 09 Roof Outside Jindal CR sheet of 1.2mm thick properly sloped & water tight. 10 False Ceiling 8mm OSL MDF- Plane White of make Leo Classic. 11 Flooring 18mm Bison Panel with Vinyl carpet. 12 Aluminium Windows Sliding Aluminium Powder Coated Windows With 4mm Glass. 13 Door Ms door with holder draft & handles. 14 Insulation 50mm glass wool insulation on wall & 25mm on ceiling. 15 Wiring All wiring of concealed type & PVC insulated copper wire. 16 Electrical Fittings  All electrical fittings in portable cabin shall be 220-240V.AC 50Hz.  Tubes, Bulkhead, Fan, switches, Sockets & Telephone.  Air conditioner point (MCB) (All type of window Air conditioning Systems as desired upon can be Installed polycab wire. 17 Earthing Earthing point will be provided for safety. 18 Outside Painting 1 coat of Epoxy primer with 2 coats of Epoxy Paint. 19 Hooks Specially formed hooks for easy lifting and shifting.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Office Cabin INR   0 INR  0
-NaN%

Office Cabin

TECHNICAL SPECIFICATION SI NO COMPONENT DESCRIPTION 01 Bottom Frame 100mmx50mm G, C Channel & pipe ISI Marked. 02 Top Frame 50mmx50mm Ms Square Pipe ISI Marked. 03 Stiffener Bottom 75mmx40mm C channel Angles & pipes ISI Marked. 04 Stiffener Top 40mmx20mm MS square pipe ISI Marked. 05 Side Post 50mmx50mm Ms square pipe ISI Marked. 06 Side Wall Stiffeners Specially formed CR sheets of make TATA / Jindal. 07 Paneling Outside Specially formed CR sheets TATA / Jindal. 08 Internal Wall Paneling 8mm OSL MDF of make Leo Classic. 09 Roof Outside Jindal CR sheet of 1.2mm thick properly sloped & water tight. 10 False Ceiling 8mm OSL MDF- Plane White of make Leo Classic. 11 Flooring 18mm Bison Panel with Vinyl carpet. 12 Aluminium Windows Sliding Aluminium Powder Coated Windows With 4mm Glass. 13 Door Ms door with holder draft & handles. 14 Insulation 50mm glass wool insulation on wall & 25mm on ceiling. 15 Wiring All wiring of concealed type & PVC insulated copper wire. 16 Electrical Fittings  All electrical fittings in portable cabin shall be 220-240V.AC 50Hz.  Tubes, Bulkhead, Fan, switches, Sockets & Telephone.  Air conditioner point (MCB) (All type of window Air conditioning Systems as desired upon can be Installed polycab wire. 17 Earthing Earthing point will be provided for safety. 18 Outside Painting 1 coat of Epoxy primer with 2 coats of Epoxy Paint. 19 Hooks Specially formed hooks for easy lifting and shifting.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Toilet Cabin INR   0 INR  0
-NaN%

Toilet Cabin

TECHNICAL SPECIFICATION : Container Dimension:–10’ (length) x 10’ (width) x 8.5’ (height). 1. M. S. Corrugated Exterior. 2. Insulated Door. Size 3’ x 6’.5’’Lockable. 3. Painting “Water Proof Paint” Safe from Rain and Sunlight. 4. Thermocol Installations on Top & 4 Sides. 5. On Four Sides Water & Fire Resistance Hylam Sheets Installed. 6. Water Pipes Installation. 7. Water tank stand on the top of the cabin. ELECTRICAL FITTINGS: - 1. Exhaust Fans. 2. Bulk Head Light Outside the Cabin. 3. Switches & Electricals Fittings. 4. 1 Bulb inside. 5. Main Cable Entry Socket with Aluminum.  Toilet (4’x4’) • IWC. • Wash Basin. • Health Faucet. • Tap. • Water tank stand.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Toilet Cabin INR   0 INR  0
-NaN%

Toilet Cabin

TECHNICAL SPECIFICATION : Container Dimension:–8’ (length) x 4’ (width) x 8.5’ (height). 1. M. S. Corrugated Exterior. 2. Insulated Door. Size 3’ x 6’.5’’Lockable. 3. Painting “Water Proof Paint” Safe from Rain and Sunlight. 4. Thermocol Installations on Top & 4 Sides. 5. On Four Sides Water & Fire Resistance Hylam Sheets Installed. 6. Water Pipes Installation. 7. Water tank stand on the top of the cabin. ELECTRICAL FITTINGS: - 1. Exhaust Fans. 2. Bulk Head Light Outside the Cabin. 3. Switches & Electricals Fittings. 4. 1 Bulb inside. 5. Main Cable Entry Socket with Aluminum.  Toilet (4’x4’) • IWC. • Wash Basin. • Health Faucet. • Tap. • Water tank stand.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Office Cabin INR   0 INR  0
-NaN%

Office Cabin

TECHNICAL SPECIFICATION SI NO COMPONENT DESCRIPTION 01 Bottom Frame 100mmx50mm G, C Channel & pipe ISI Marked. 02 Top Frame 50mmx50mm Ms Square Pipe ISI Marked. 03 Stiffener Bottom 75mmx40mm C channel Angles & pipes ISI Marked. 04 Stiffener Top 40mmx20mm MS square pipe ISI Marked. 05 Side Post 50mmx50mm Ms square pipe ISI Marked. 06 Side Wall Stiffeners Specially formed CR sheets of make TATA / Jindal. 07 Paneling Outside Specially formed CR sheets TATA / Jindal. 08 Internal Wall Paneling 8mm OSL MDF of make Leo Classic. 09 Roof Outside Jindal CR sheet of 1.2mm thick properly sloped & water tight. 10 False Ceiling 8mm OSL MDF- Plane White of make Leo Classic. 11 Flooring 18mm Bison Panel with Vinyl carpet. 12 Aluminium Windows Sliding Aluminium Powder Coated Windows With 4mm Glass. 13 Door Ms door with holder draft & handles. 14 Insulation 50mm glass wool insulation on wall & 25mm on ceiling. 15 Wiring All wiring of concealed type & PVC insulated copper wire. 16 Electrical Fittings  All electrical fittings in portable cabin shall be 220-240V.AC 50Hz.  Tubes, Bulkhead, Fan, switches, Sockets & Telephone.  Air conditioner point (MCB) (All type of window Air conditioning Systems as desired upon can be Installed polycab wire. 17 Earthing Earthing point will be provided for safety. 18 Outside Painting 1 coat of Epoxy primer with 2 coats of Epoxy Paint. 19 Hooks Specially formed hooks for easy lifting and shifting.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Office Cabin INR   0 INR  0
-NaN%

Office Cabin

TECHNICAL SPECIFICATION SI NO COMPONENT DESCRIPTION 01 Bottom Frame 100mmx50mm G, C Channel & pipe ISI Marked. 02 Top Frame 50mmx50mm Ms Square Pipe ISI Marked. 03 Stiffener Bottom 75mmx40mm C channel Angles & pipes ISI Marked. 04 Stiffener Top 40mmx20mm MS square pipe ISI Marked. 05 Side Post 50mmx50mm Ms square pipe ISI Marked. 06 Side Wall Stiffeners Specially formed CR sheets of make TATA / Jindal. 07 Paneling Outside Specially formed CR sheets TATA / Jindal. 08 Internal Wall Paneling 8mm OSL MDF of make Leo Classic. 09 Roof Outside Jindal CR sheet of 1.2mm thick properly sloped & water tight. 10 False Ceiling 8mm OSL MDF- Plane White of make Leo Classic. 11 Flooring 18mm Bison Panel with Vinyl carpet. 12 Aluminium Windows Sliding Aluminium Powder Coated Windows With 4mm Glass. 13 Door Ms door with holder draft & handles. 14 Insulation 50mm glass wool insulation on wall & 25mm on ceiling. 15 Wiring All wiring of concealed type & PVC insulated copper wire. 16 Electrical Fittings  All electrical fittings in portable cabin shall be 220-240V.AC 50Hz.  Tubes, Bulkhead, Fan, switches, Sockets & Telephone.  Air conditioner point (MCB) (All type of window Air conditioning Systems as desired upon can be Installed polycab wire. 17 Earthing Earthing point will be provided for safety. 18 Outside Painting 1 coat of Epoxy primer with 2 coats of Epoxy Paint. 19 Hooks Specially formed hooks for easy lifting and shifting.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Office Cabin INR   0 INR  0
-NaN%

Office Cabin

TECHNICAL SPECIFICATION SI NO COMPONENT DESCRIPTION 01 Bottom Frame 100mmx50mm G, C Channel & pipe ISI Marked. 02 Top Frame 50mmx50mm Ms Square Pipe ISI Marked. 03 Stiffener Bottom 75mmx40mm C channel Angles & pipes ISI Marked. 04 Stiffener Top 40mmx20mm MS square pipe ISI Marked. 05 Side Post 50mmx50mm Ms square pipe ISI Marked. 06 Side Wall Stiffeners Specially formed CR sheets of make TATA / Jindal. 07 Paneling Outside Specially formed CR sheets TATA / Jindal. 08 Internal Wall Paneling 8mm OSL MDF of make Leo Classic. 09 Roof Outside Jindal CR sheet of 1.2mm thick properly sloped & water tight. 10 False Ceiling 8mm OSL MDF- Plane White of make Leo Classic. 11 Flooring 18mm Bison Panel with Vinyl carpet. 12 Aluminium Windows Sliding Aluminium Powder Coated Windows With 4mm Glass. 13 Door Ms door with holder draft & handles. 14 Insulation 50mm glass wool insulation on wall & 25mm on ceiling. 15 Wiring All wiring of concealed type & PVC insulated copper wire. 16 Electrical Fittings  All electrical fittings in portable cabin shall be 220-240V.AC 50Hz.  Tubes, Bulkhead, Fan, switches, Sockets & Telephone.  Air conditioner point (MCB) (All type of window Air conditioning Systems as desired upon can be Installed polycab wire. 17 Earthing Earthing point will be provided for safety. 18 Outside Painting 1 coat of Epoxy primer with 2 coats of Epoxy Paint. 19 Hooks Specially formed hooks for easy lifting and shifting.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Toilet Cabin INR   0 INR  0
-NaN%

Toilet Cabin

TECHNICAL SPECIFICATION : Container Dimension:–8’ (length) x 4’ (width) x 8.5’ (height). 1. M. S. Corrugated Exterior. 2. Insulated Door. Size 3’ x 6’.5’’Lockable. 3. Painting “Water Proof Paint” Safe from Rain and Sunlight. 4. Thermocol Installations on Top & 4 Sides. 5. On Four Sides Water & Fire Resistance Hylam Sheets Installed. 6. Water Pipes Installation. 7. Water tank stand on the top of the cabin. ELECTRICAL FITTINGS: - 1. Exhaust Fans. 2. Bulk Head Light Outside the Cabin. 3. Switches & Electricals Fittings. 4. 1 Bulb inside. 5. Main Cable Entry Socket with Aluminum.  Toilet (4’x4’) • IWC. • Wash Basin. • Health Faucet. • Tap. • Water tank stand.

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
1
false